Symptom
- Anomalies observed with formula inside Calculated Structures when performing delta calculations between different plan versions.
- System shows the results from measures instead of calculated structure members.
Environment
- SAP Datasphere
- Analytic Model
Cause
The Structure Members collision handling settings. The configuration prioritize the calculation from measures or structure members.
Resolution
- Open the Analytic Model and go to the Structure Members settings.
- Configure Collision Handling to prioritize the calculated structure member.
- Preview the Analytic Model and verify the values.
See Also
- Refer to: Configure Collision Handling
Keywords
calculated structure member, collision handling, calculated measure, restricted structure member, analytic model, structure member , KBA , DS-MD-AM , Analytic Model , Problem