SAP Knowledge Base Article - Public

3793558 - Error: "checking credentials: rejected" in Process Intelligence

Symptom

Error: "checking credentials: rejected" in Process Intelligence

Reproducing the Issue

Validate the connection and check for a mention of "SNC_MODE=1", but your extra connection arguments contain just SNCSSO

Cause

If you have the extra connection argument SNCSSO but haven't specified a value it will default to  SNCSSO = 1 which means the connection will attempt to use SSO.

The SNCSSO parameter was added to the on premise connector's allowed property list in v1.1135.0 (released 2025-03-17)

Resolution

Add SNCSSO=0 in the extra connection arguments section of your RFC connection to disable SSO calls

See Also

Setup SNC with RFC connector

Keywords

KBA , BPI-SIG-PI-DS , Data Source (CSV, Connector) , Known Error

Product

SAP Signavio Process Intelligence all versions