Symptom
When trying to validate, simulate or migrate a migration object, the following error appears:
Call to function module /1LT/<SID>OLC_100000000000999 failed
Message no. DMCLG863
When the migration cockpit is used, it generates runtime objects (such as function modules) in the backend system to transfer the data.
There are some runtime objects which are SID specific, for example:
If the system had 'DEV' as SID, the runtime object will be named: /1LT/DEVOLC_100000000000999
But, most of the times when a system copy is made, the SID of the system is changed, for example: DEV becomes DAS
However, if the SID is changed along the system copy, the runtime object's name does not change, it will still be: /1LT/DEVOLC_100000000000999
This is incorrect, the name of runtime object must contain the correct SID, which would be DAS and the runtime object name must be: /1LT/DASOLC_100000000000999