Symptom
- Bulk smart meter reading request is generated for meters with multiple read-relevant registers.
- Communication infrastructure splits the bulk request into individual SmartMeterMeterReadingDocumentERPCreateRequest_Out per register (for example, KWH-DEL, KWH-REC, KW-PEAK) and sends them to the head-end system.
- The head-end system returns individual SmartMeterMeterReadingDocumentERPCreateConfirmation_In messages.
- When multiple requests for the same meter are processed, the device is locked, preventing other requests from being processed.
- Affected confirmations remain in status "04 – Action open" instead of "01 – Action Completed successfully".
Read more...
Environment
- SAP for Utilities as Part of SAP ERP, release IS-UT 600 and higher.
- SAP S/4HANA, release IS-UT 801 and higher.
Product
SAP ERP all versions ; SAP S/4HANA all versions
Keywords
SmartMeterMeterReadingDocumentERPBulkCreateRequest_Out, SmartMeterMeterReadingDocumentERPCreateRequest_Out, SmartMeterMeterReadingDocumentERPCreateConfirmation_In, device lock, status 04 Action open, status 01 Action Completed successfully, FEH cockpit, /SAPPO/PPO2, Error and Conflict Handler, IS-U, Utilities, meter reading, parallel processing, enqueue locking , KBA , IS-U-DM-MR , Meter Readings , How To